ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento63041
Número CIS 94-1664
ISSN - Título de la serie 0002-8894 - American Industrial Hygiene Association Journal
Año 1993
Número de serie
Autor(es) Zellers E.T., Sulewski R.
Título Modeling the temperature dependence of N-methylpyrrolidone permeation through butyl- and natural-rubber gloves
Información bibliográfica Sep. 1993, Vol.54, No.9, p.465-479. Illus. 52 ref.
Resumen Study of breakthrough time of N-methylpyrrolidone for butyl and natural rubber gloves. The gloves were tested at four temperatures from 25-50°C. The butyl rubber glove did not show any breakthrough after four hours. The natural rubber gloves showed permeation rates applying well with the Arrhenius relationship. Extrapolation of the temperature to 70-93°C gave breakthrough values of less than 0.5-2 minutes. Experimental values were compared with permeation models. The Fickian diffusion equation gave values of breakthrough time and steady-state permeation time within 23 and 50% respectively of the experimental values.
Descriptores (primarios) guantes de protección; equipo de protección individual; metilpirrolidinona; pruebas de permeabilidad; duración del servicio
Descriptores (secundarios) valoración del material; estudio comparado; modelos matemáticos
Tipo de documento D - Artículos periódicos
País / Estado o ProvinciaEstados Unidos
Tema(s) Protección individual
Broad subject area(s) Riesgos químicos
Navegación por categoria(s) Heterocyclic compounds
Hand and arm protection
Respiratory protection
Personal protection