ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento47683
Número CIS 87-599
ISSN - Título de la serie 0024-449X - Litejnoe proizvodstvo
Año 1986
Número de serie
Autor(es) Balev A.I., Kul'pa L.S., Jančuk V.F.
Título Development of a two-zone exhaust system for removing gases from low-capacity arc furnaces
Título original Razrabotka processa dvuhzonnogo gazootbora dugovyh pečej maloj vmestimosti [en ruso]
Información bibliográfica July 1986, No.7, p.24.
Resumen When one metric ton of steel is refined in an electric arc furnace, 80-90kg of carbon monoxide, approx. 10kg fine dust, as well as sulfur monoxide, nitrogen and other substances are set free. The effectiveness of exhaust hoods rarely exceeds 70%. Description of a two-zone system which enables an effectiveness of 93-95% to be attained by exhausting 16,000-18,000m3/h (t=80°C): In the first zone, the gases are drawn from the charging door, and in the second, through the openings in the roof round the electrodes, from where the gases pass into a telescopic and articulated duct allowing the furnace to be tilted. While the gases are exhausted, air penetrates into the furnace and helps to burn part of the carbon monoxide.
Descriptores (primarios) aspiración localizada; óxido de carbono; acerías; fundiciones; hornos de arco
Descriptores (secundarios) dispositivos de aspiración; descripción del material
Tipo de documento D - Artículos periódicos
Tema(s) Metalurgia, trabajo de los metales
Broad subject area(s) Riesgos químicos
Navegación por categoria(s) Inorganic substances
Iron and steel industry
Ventilation
Carbon monoxide
Foundries, metalcasting and forging operations