Autor(es) Bagon D.A., Warwick C.J., Brown R.H.
Título Evaluation of total isocyanate-in-air method using 1-(2 methoxyphenyl)piperazine and HPLC
Información bibliográfica Jan. 1984, Vol.45, No.1, p.39-43. 6 ref.
Resumen This high-pressure liquid chromatography method has been developped to meet the requirements of the "common control limit" for workplace exposure to all isocyantes recently promulgated in the United Kingdom (20µg NCO/m3 for an 8h TWA). It has been modified to measure both the monomer and prepolymer. A dual detection system (electrochemical and UV) is used to identify the isocyanate derivatives and quantify them by reference to a monomer standard. The precision of the method is >10% over the range 35 to 140µg(NCO)/m3 for a 10min sample. Accuracy is ±19%.
Descriptores (primarios) valores umbrales; análisis químico; isocianatos
Descriptores (secundarios) cromatografía en fase liquida a alta presión
Tipo de documento D - Artículos periódicos
Tema(s) Sustancias tóxicas y peligrosas
Broad subject area(s)
Navegación por categoria(s) Cyano compounds
Occupational exposure limits
Isocyanates