ID (ISN) del documento | 42685 |
Número CIS |
84-1630 |
ISSN - Título de la serie |
0002-8894 - American Industrial Hygiene Association Journal |
Año |
1984 |
Número de serie |
|
Autor(es) |
Bagon D.A., Warwick C.J., Brown R.H. |
Título |
Evaluation of total isocyanate-in-air method using 1-(2 methoxyphenyl)piperazine and HPLC |
Información bibliográfica |
Jan. 1984, Vol.45, No.1, p.39-43. 6 ref. |
Resumen |
This high-pressure liquid chromatography method has been developped to meet the requirements of the "common control limit" for workplace exposure to all isocyantes recently promulgated in the United Kingdom (20µg NCO/m3 for an 8h TWA). It has been modified to measure both the monomer and prepolymer. A dual detection system (electrochemical and UV) is used to identify the isocyanate derivatives and quantify them by reference to a monomer standard. The precision of the method is >10% over the range 35 to 140µg(NCO)/m3 for a 10min sample. Accuracy is ±19%. |
Descriptores (primarios) |
valores umbrales; análisis químico; isocianatos |
Descriptores (secundarios) |
cromatografía en fase liquida a alta presión |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Sustancias tóxicas y peligrosas
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Cyano compounds Occupational exposure limits Isocyanates
|