ID (ISN) del documento | 37336 |
Número CIS |
82-334 |
Año |
1980 |
Número de serie |
|
Autor(es) |
Bakonyi T., Czabai I. |
Título |
Electrostatic charging in the course of high pressure, airless spraying and prevention of the probable accidents |
Información bibliográfica |
Published in "Elöadások, kutatások, publikációk" 2. szám, SZOT, Munkavédelmi Tudományos Kutato Intézet, Budapest, Hungary, 1981, p.65-75. Illus. |
Resumen |
Measurements were made, in the laboratory and at work sites, of the degree of charging of paint mist, the maximum spark discharge energy and the safety of working conditions during high-pressure airless paint spraying. Charge build-up and separation occurred in the space between the spray gun and the workplace, and on the workpiece. The differences in charge potential and static accumulation were great enough that the energy of a probable spark discharge could exceed the minimum ignition energy of the paint mist. Charge accumulation and spark discharge can be prevented by grounding of the workpiece and charge drainage through an eliminator. Dangers of personal charging are minimised by conductive clothing, footwear and flooring. |
Descriptores (primarios) |
electricidad estática; pintura con pistola; pulverización a presión; prevención de las explosiones; atmósferas explosivas |
Descriptores (secundarios) |
eliminación de la electricidad estática; determinación experimental; toma a tierra |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Electricidad
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Electricidad Surface treatment Explosions
|