ID (ISN) del documento | 28000 |
Número CIS |
77-1654 |
ISSN - Título de la serie |
0959-8146 - British Medical Journal |
Año |
1977 |
Número de serie |
|
Autor(es) |
Armstrong R.F., Kershaw E.J., Bourne S.P., Strunin L. |
Título |
Anaesthetic waste gas scavenging systems. |
Información bibliográfica |
9 Apr. 1977, Vol.1, No.6066, p.941-943. 13 ref. |
Resumen |
The Department of Health and Social Security in the United Kingdom has recommended that waste anaesthetic scavenging systems should be installed in operating theatres to reduce pollution. Tests with 3 passive and 2 active systems are reported. All reduced halothane levels significantly, the combination of an active system and semi-closed circuitry being the most effective. Some of the benefits of a scavenging system may be lost if gases can still escape through leaks. |
Descriptores (primarios) |
anestésicos por inhalación; hospitales; dispositivos de aspiración; bloques quirúrgicos |
Descriptores (secundarios) |
halotano; valoración del material |
Tipo de documento |
- |
Tema(s) |
Sustancias tóxicas y peligrosas
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Ventilation Health care services
|