Número de serie
Autor(es) Armstrong R.F., Kershaw E.J., Bourne S.P., Strunin L.
Título Anaesthetic waste gas scavenging systems.
Información bibliográfica 9 Apr. 1977, Vol.1, No.6066, p.941-943. 13 ref.
Resumen The Department of Health and Social Security in the United Kingdom has recommended that waste anaesthetic scavenging systems should be installed in operating theatres to reduce pollution. Tests with 3 passive and 2 active systems are reported. All reduced halothane levels significantly, the combination of an active system and semi-closed circuitry being the most effective. Some of the benefits of a scavenging system may be lost if gases can still escape through leaks.
Descriptores (primarios) anestésicos por inhalación; hospitales; dispositivos de aspiración; bloques quirúrgicos
Descriptores (secundarios) halotano; valoración del material
Tipo de documento -
Tema(s) Sustancias tóxicas y peligrosas
Broad subject area(s)
Navegación por categoria(s) Ventilation
Health care services