ID (ISN) del documento | 20023 |
Número CIS |
74-23 |
Año |
1973 |
Número de serie |
|
Autor(es) |
Balemans A.W.M., Bezemer J., Van Elburg B. |
Título |
Report on the causes of the explosion in a gunpowder factory at Muiden, 8 December 1972 |
Título original |
Rapport over oorzaak explosie kruitfabriek te Muiden, 8 december 1972 [en holandés] |
Información bibliográfica |
Arbeidsinspectie, Wittevrouwensingel 27, Utrecht, Netherlands, June 1973. 51p. Illus. Gratis. |
Resumen |
Results of the inquiry carried out by the Netherlands Labour Inspectorate into the causes of an explosion at the Muiden gunpowder factory which resulted in 2 deaths and a large number of persons injured. The explosion was very probably due to wrong operation in uncoupling an air drier filled with porous hunting powder: an ungrounded conductor (the cover of the drier) was elctrostatically charged by the powder and caused ignition. |
Descriptores (primarios) |
chispas eléctricas; explosiones; pólvora negra; electricidad estática |
Descriptores (secundarios) |
Países Bajos; informe de la encuesta; secado |
Tipo de documento |
E - Libros, informes, actas |
Tema(s) |
Incendios, explosiones
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Explosions Electricidad
|