ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento112545
Número CIS 12-0256
Año 2009
Número de serie RR 725
Autor(es) White J.
Health and Safety Executive
Título MALDI/TOF/MS analysis of isocyanates and other hazardous workplace chemicals
Información bibliográfica HSE Books, P.O. Box 1999, Sudbury, Suffolk CO10 2WA, United Kingdom, 2009. viii, 24p. Illus. 18 ref.
Acceso Internet MALDI/TOF/MS_analysis_[INTERNET_FREE_ACCESS] [en inglés]
Resumen Mass spectrometry has long been used to analyze samples taken in the workplace, and can be combined with other techniques to increase sensitivity, selectivity and accuracy. The work summarized in this report examines the application of the recently-developed Matrix Assisted Laser Desorption Ionization/ time-of-flight/ mass spectrometry (MALDI/TOF/MS) technique to the analysis of isocyanates in air and biocides in soil samples. Findings are discussed.
Descriptores (primarios) Reino Unido; isocianatos; biocidas; toma de muestras y análisis; descripción del procedimiento
Descriptores (secundarios) láseres; espectrometría de masa; fiabilidad; instituciones publicas de prevencion; informe
Tipo de documento E - Libros, informes, actas
País / Estado o ProvinciaReino Unido
Tema(s) Sustancias tóxicas y peligrosas
Broad subject area(s) Riesgos químicos
Navegación por categoria(s) Exposure evaluation
Isocyanates