ID (ISN) del documento | 109014 |
Número CIS |
09-187 |
ISSN - Título de la serie |
1545-9624 - Journal of Occupational and Environmental Hygiene |
Año |
2007 |
Número de serie |
|
Autor(es) |
First M., Rudnick S.N., Banahan K.F., Vincent R.L., Brickner P.W. |
Título |
Fundamental factors affecting upper-room ultraviolet germicidal irradiation - Part I. Experimental |
Información bibliográfica |
May 2007, Vol.4, No.5, p.321-331. Illus. 17 ref. |
Resumen |
The objective of this research was to study the factors that relate to the effectiveness of upper-room ultraviolet germicidal irradiation for inactivating airborne microorganisms. The work was conducted in a laboratory chamber designed and furnished to simulate a hospital room. Nebulized Serratia marcescens, Bacillus subtilis spores and vaccinia virus were used as test aerosols. Data were collected from steady-state experiments comparing the number of viable organisms in the chamber air remaining with UV lamps turned on to the number with UV lamps turned off. UV power level had a strong influence but was fully effective only in the presence of strong air mixing. In conclusion, an ultraviolet installation is a complex system that requires careful integration of UV luminaries, UV power and room ventilation systems. See also CIS 09-000, ISN 6. |
Descriptores (primarios) |
radiación ultravioleta; hospitales; prevención del contagio; microrganismos |
Descriptores (secundarios) |
bacterias patógenas; virus; laboratorios de pruebas; descripción del procedimiento; desinfección del aire; sistemas de ventilación; valoración del método; fiabilidad |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Cemercio, servicios, oficinas
|
Broad subject area(s) |
Riesgos biológicos Riesgos físicos
|
Navegación por categoria(s) |
Non-ionizing radiation Health care services
|