Title Study of the reliability of emission sound pressure level measurements using the 3-component intensity method
Original title Untersuchungen zur Messunsicherheit des Emissionsschalldruckpegels bestimmt durch das 3-Komponenten-Intensitäts-Verfahren [in German]
Bibliographic information Wirtschaftsverlag NW, Postfach 10 11 10, 27511 Bremerhaven, Germany, 2002. 77p. Illus. 22 ref. Price: EUR 11.50.
Abstract This report describes the work carried out for the purpose of defining the conditions of application of a method for determining emission sound pressure levels based on the technique of recording three Cartesian sound intensity components. A single measurement enables the calculation of the complete sound spectra and of any frequency-weighted quantity. Over 400 acoustical situations were tested, including in rooms with K3 values of up to 14.5dB, significant background noise, composed sound sources, measurements in shadow positions and sources with high directionality. The method was found to be applicable in a wide variety of conditions and was incorporated into the ISO 11205 standard.
Descriptors (primary) noise level; noise measurement; reliability
Descriptors (secondary) sound intensity; report; Germany; standard; sound spectrum criteria; noise dosimetry; description of technique; ISO
Document type E - Books, reports, proceedings
Country / State or ProvinceGermany
Subject(s) Noise, hearing and vibration
Broad subject area(s) Physical hazards