ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)75799
CIS number 00-1686
Year 1996
Convention or series no.
Author(s) Sernia S.
Title Evaluation of benzene concentration in exhaled air as a biological indicator in petrol station attendants
Original title Valutazione della concentrazione di benzene nell'area espirata quale indicatore biologico negli addetti al rifornimento di carburante [in Italian]
Bibliographic information Istituto Italiana di Medicina Sociale, Via P.S. Mancini, 28, 00196 Roma, Italy, 1996. 103p. Illus. 47 ref.
Abstract The purpose of this study was to find out if the determination of benzene concentrations in exhaled air from petrol (gasoline) station attendants is a useful way to monitor exposure to low environmental levels of benzene. In an Italy-wide survey, it was found that a strong correlation indeed exists between exposure levels and exhaled air concentration, particularly when there is a delay between exposure and sampling (correlation r=0.67 with a 2hr delay and r=0.79 with a 14-16hr delay). Determination methods and relevant legal texts are given in the appendix.
Descriptors (primary) benzene; filling stations; determination in exhaled air; exposure tests; determination in air
Descriptors (secondary) legislation; Italy
Document type E - Books, reports, proceedings
Country / State or ProvinceItaly
Subject(s) Toxic and dangerous substances
Broad subject area(s) Chemical safety
Browse category(ies) Road transportation
Biological monitoring
Aromatic hydrocarbons