ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)70195
CIS number 97-2019
ISSN - Serial title 0019-8366 - Industrial Health
Year 1997
Convention or series no.
Author(s) Maeda S., et al.
Title A comparison of vibrotactile thresholds on the finger obtained with ISO type equipment and Japanese equipment
Bibliographic information July 1997, Vol.35, No.3, p.343-352. Illus. 28 ref.
Abstract A vibrotactile threshold measurement system based on specifications of the International Organization for Standardization (draft standard ISO/CD 13091) was compared with a system currently used in Japan. Measurements were carried out on ten subjects under conditions similar to those outlined in the draft standard. Vibrotactile thresholds measured with the Japanese equipment were higher than those measured with the ISO equipment. In addition, the ISO equipment showed greater repeatability of results. Vibrotactile threshold determinations should take into account the experimental conditions (vibration frequency, area of contact, contact force, push force, and finger temperature).
Descriptors (primary) hand-arm vibration; vibration perception threshold
Descriptors (secondary) evaluation of equipment; comment on standard; fingers
Document type D - Periodical articles
Country / State or ProvinceJapan
Subject(s) Noise, hearing and vibration
Broad subject area(s) Physical hazards
Browse category(ies) Vibration