Document ID (ISN) | 70195 |
CIS number |
97-2019 |
ISSN - Serial title |
0019-8366 - Industrial Health |
Year |
1997 |
Convention or series no. |
|
Author(s) |
Maeda S., et al. |
Title |
A comparison of vibrotactile thresholds on the finger obtained with ISO type equipment and Japanese equipment |
Bibliographic information |
July 1997, Vol.35, No.3, p.343-352. Illus. 28 ref. |
Abstract |
A vibrotactile threshold measurement system based on specifications of the International Organization for Standardization (draft standard ISO/CD 13091) was compared with a system currently used in Japan. Measurements were carried out on ten subjects under conditions similar to those outlined in the draft standard. Vibrotactile thresholds measured with the Japanese equipment were higher than those measured with the ISO equipment. In addition, the ISO equipment showed greater repeatability of results. Vibrotactile threshold determinations should take into account the experimental conditions (vibration frequency, area of contact, contact force, push force, and finger temperature). |
Descriptors (primary) |
hand-arm vibration; vibration perception threshold |
Descriptors (secondary) |
evaluation of equipment; comment on standard; fingers |
Document type |
D - Periodical articles |
Country / State or Province | Japan |
Subject(s) |
Noise, hearing and vibration
|
Broad subject area(s) |
Physical hazards
|
Browse category(ies) |
Vibration
|