Document ID (ISN) | 69677 |
CIS number |
97-1615 |
ISSN - Serial title |
0002-8894 - American Industrial Hygiene Association Journal |
Year |
1997 |
Convention or series no. |
|
Author(s) |
McNabb N., Kostiuk J., Brauer M. |
Title |
Improved ice arena air quality with the use of a three-way catalytic converter and fuel management system |
Bibliographic information |
Aug. 1997, Vol.58, No.8, p.608-612. 24 ref. |
Abstract |
Nitrogen dioxide concentrations in an ice arena were evaluated before and after a three-way catalytic converter and fuel management system were retrofitted to a 7-year old ice resurfacing machine. Air sampling indicated an 87% reduction in airborne nitrogen dioxide concentrations after the retrofit. Carbon monoxide levels were also reduced by 57%. It is recommended that this option be used in conjunction with other measures to minimize indoor air concentrations of combustion exhaust gases. |
Descriptors (primary) |
nitrogen dioxide; sports facilities; exhaust gases; carbon monoxide |
Descriptors (secondary) |
air sampling |
Document type |
D - Periodical articles |
Country / State or Province | Canada |
Subject(s) |
Environmental pollution
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Inorganic substances Carbon monoxide Entertainment services and sports
|