Document ID (ISN) | 68945 |
CIS number |
97-867 |
ISSN - Serial title |
0002-8894 - American Industrial Hygiene Association Journal |
Year |
1997 |
Convention or series no. |
|
Author(s) |
Kuo H.W., Lai J.S., Lin T.I. |
Title |
Concentration and size distribution of airborne hexavalent chromium in electroplating factories |
Bibliographic information |
Jan. 1997, Vol.58, No.1, p.29-32. 18 ref. |
Abstract |
Area and personal sampling for hexavalent chromium were carried out at four electroplating factories in Taiwan. Samples were collected using a particle fractionating sampler and were analyzed using visible spectrophotometry. A comparison of three types of factories (chromium, nickel-chromium and zinc) showed that the highest concentrations of chromium were found in chromium electroplating factories near the electroplating tank. Chromium particles obtained through area sampling yielded a mass median diameter between 1.67 and 6.38µm, and those from personal sampling between 0.75 and 4.73µm. Both and large and small chromium particles may have effects on the respiratory system. |
Descriptors (primary) |
airborne dust; particle size distribution; chromium and compounds; dust measurement; electroplating |
Descriptors (secondary) |
personal sampling; chromium; determination in air; Taiwan (China) |
Document type |
D - Periodical articles |
Country / State or Province | Taiwan (China) |
Subject(s) |
Dust, aerosols and related diseases
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Surface treatment Inorganic substances
|