Document ID (ISN) | 53827 |
CIS number |
90-1038 |
ISSN - Serial title |
0172-8261 - Audiologische Akustik - Audiological Acoustics |
Year |
1988 |
Convention or series no. |
|
Author(s) |
Welzl-Müller K., Stephan K. |
Title |
Speech recognition performance with hearing aids with and without background noise |
Original title |
Sprachverständlichkeit mit Hörgerät - ohne und mit Störschall [in German] |
Bibliographic information |
1988, Vol.27, No.4, p.108-114, 119. Illus. 14 ref. |
Abstract |
The influence of hearing aids on the speech intelligibility threshold (i.e. the sound pressure level required to understand 50% of spoken words) without background noise and on the required signal-to-noise ratio was studied on 199 men and 93 women aged 40 to 85 years. It was found that hearing aids improved speech intelligibility but had no influence on the signal-to-noise ratio. |
Descriptors (primary) |
background noise; speech intelligibility; hearing aids; speech interference |
Descriptors (secondary) |
hearing-aid wearers; speech audiometry |
Document type |
D - Periodical articles |
Subject(s) |
Psychology and sociology
|
Broad subject area(s) |
Physiology, ergonomics
|
Browse category(ies) |
Noise Ergonomics
|