Document ID (ISN) | 53206 |
CIS number |
90-168 |
ISSN - Serial title |
Tag für Tag |
Year |
1989 |
Convention or series no. |
|
Title |
What to observe when setting up and operating photocopying machines |
Original title |
Fotokopierer. Was beim Aufstellen und Betrieb zu beachten ist [in German] |
Bibliographic information |
1989, No.5, p.20-21. Illus. |
Abstract |
Measures for the prevention of health hazards due to work with photocopiers include: (1) installation of photocopiers apart from other offices in a well ventilated room; (2) use of an ozone filter and/or exhaust system when there is frequent use of the photocopier in a closed room; (3) wearing of protective gloves when handling pulverised toner, in order to avoid skin contact; (4) prevention of inhalation of toner by keeping it sealed and avoiding spillage; (5) proper maintenance of photocopiers. |
Descriptors (primary) |
ozone; duplicating; printing inks; nitrogen oxides |
Descriptors (secondary) |
occupational hygiene; protective gloves; nitrogen dioxide; health hazards; offices; limitation of exposure; ventilation; workplaces |
Document type |
D - Periodical articles |
Subject(s) |
Other equipment and plant
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Printing, photography and photocopying industry Inorganic substances
|