ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)51376
CIS number 89-612
Year 1987
Convention or series no.
Author(s) Howie R.M., Coleman G.C., Graveling R.A., Graves R.G., Nicholl A.G.M., Groat S., Wildblood R., Crawford N.P., Dodgson J.
Title Development of a powered helmet respirator suitable for use in coalmines
Bibliographic information Institute of Occupational Medicine, Roxburgh Place, Edinburgh EH8 9SU, United Kingdom, 1987. 104p. Illus. 19 ref. Appendices. Price: GBP 10.00.
Abstract Contents of this report: work programme; ergonomic assessment of the AHG powered helmet respirator (PHR); development of a prototype PHR; development of fan/filter systems, headshells, visor assemblies; specification of the Institute of Occupational Medicine (IOM) prototype PHR; ergonomic assessment of the final IOM prototype PHR; mobility, communication, physiological and wearer acceptance trials.
Descriptors (primary) particulate removing respirators; coal mining; positive supply filter respirators
Descriptors (secondary) dust helmets; evaluation of equipment; ergonomic evaluation; report; United Kingdom
Document type E - Books, reports, proceedings
Subject(s) Personal protection
Broad subject area(s) Chemical safety
Browse category(ies) Respiratory protection
Mining and quarrying