CISDOC database
Document ID (ISN) | 51376 |
CIS number |
89-612 |
Year |
1987 |
Convention or series no. |
|
Author(s) |
Howie R.M., Coleman G.C., Graveling R.A., Graves R.G., Nicholl A.G.M., Groat S., Wildblood R., Crawford N.P., Dodgson J. |
Title |
Development of a powered helmet respirator suitable for use in coalmines |
Bibliographic information |
Institute of Occupational Medicine, Roxburgh Place, Edinburgh EH8 9SU, United Kingdom, 1987. 104p. Illus. 19 ref. Appendices. Price: GBP 10.00. |
Abstract |
Contents of this report: work programme; ergonomic assessment of the AHG powered helmet respirator (PHR); development of a prototype PHR; development of fan/filter systems, headshells, visor assemblies; specification of the Institute of Occupational Medicine (IOM) prototype PHR; ergonomic assessment of the final IOM prototype PHR; mobility, communication, physiological and wearer acceptance trials. |
Descriptors (primary) |
particulate removing respirators; coal mining; positive supply filter respirators |
Descriptors (secondary) |
dust helmets; evaluation of equipment; ergonomic evaluation; report; United Kingdom |
Document type |
E - Books, reports, proceedings |
Subject(s) |
Personal protection
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection Mining and quarrying
|
|
|
|
|
|