ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)51263
CIS number 89-322
ISSN - Serial title 0019-9281 - Management-Zeitschrift IO
Year 1988
Convention or series no.
Author(s) Hahn H.
Title Illumination and flexibility in the office
Original title Beleuchtung und Flexibilität im Büro [in German]
Bibliographic information Mar. 1988, Vol.57, No.3, p.153-155. Illus. 4 ref.
Abstract In order to avoid glare from paper and from computer terminals, the luminance level in offices should range from 200 to 400cd/m2 and illumination should be indirect. If the required illumination of 750lux in drafting rooms is supplied by ceiling-mounted lamps alone then the contrast on terminal screens is too low. Optimum lighting is achieved by a combination of ceiling-mounted lamps of 20W/m2 and direct light from individual lamps for each upright drawing board.
Descriptors (primary) lighting; visual comfort; illumination design; offices
Descriptors (secondary) illumination levels; glare; optimization; artificial lighting
Document type D - Periodical articles
Subject(s) Lighting, colour and vision
Broad subject area(s) Physiology, ergonomics
Browse category(ies) Lighting and colour
Office work