ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)49969
CIS number 88-1282
ISSN - Serial title 0002-8894 - American Industrial Hygiene Association Journal
Year 1987
Convention or series no.
Author(s) Berardinelli S.P., Rusczek R.A., Mickelsen R.L.
Title A portable chemical protective clothing test method: Application at a chemical plant
Bibliographic information Sep. 1987, Vol.48, No.9, p.804-808. Illus. 9 ref.
Abstract This survey evaluated 6 raw materials that have a potential for skin absorption: aniline, cyclohexylamine, diisopropylamine, tert-butylamine, morpholine and carbon disulfide. Five generic glove materials were tested against these chemicals: nitrile, neoprene, polyvinylchloride, natural latex and natural rubber. The NIOSH chemical permeation portable test system was used to generate breakthrough time data. The results were compared to permeation data reported in the literature that were obtained by using the ASTM F739-85 test method. Aniline has too low a vapour pressure for reliable analysis on the portable direct reading detectors used. The chemical permeation test system provided comparable, reliable permeation data for the other tested chemicals.
Descriptors (primary) chemical protective clothing; chemical industry; permeability testing; equipment testing; evaluation of technique
Descriptors (secondary) protective gloves; carbon disulfide; morpholine; description of technique; tert-butylamine; cyclohexylamine; aniline; diisopropylamine
Document type D - Periodical articles
Subject(s) Chemicals, plastics and rubber
Broad subject area(s) Chemical safety
Browse category(ies) Protective clothing
Chemical industry