Document ID (ISN) | 49836 |
CIS number |
88-919 |
ISSN - Serial title |
0002-8894 - American Industrial Hygiene Association Journal |
Year |
1987 |
Convention or series no. |
|
Author(s) |
Man V.L., Bastecki V., Vandal G., Bentz A.P. |
Title |
Permeation of protective clothing materials: Comparison of liquid contact, liquid splashes and vapors on breakthrough times |
Bibliographic information |
June 1987, Vol.48, No.6, p.551-555. Illus. 5 ref. |
Abstract |
The US standard test method for permeability (ASTM F739-81) involves 3h continuous contact between liquid and material. This may not truly reflect real-world conditions. A simply-modified standard test procedure was evaluated by using 2 suit materials and several common organic liquids. The splash test is an effective method; the wettability of the material is a significant factor. |
Descriptors (primary) |
chemical protective clothing; chemical products; permeability testing; spills; service life; evaluation of technique |
Descriptors (secondary) |
tetrahydrofuran; dichloromethane; chloroform; acetone; description of technique; styrene; xylene; equipment testing; butanone |
Document type |
D - Periodical articles |
Subject(s) |
Personal protection
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection Protective clothing
|