Author(s) |
Pimental N.A., Cosimini H.M., Sawka M.N., Wenger C.B. |
Title |
Effectiveness of an air-cooled vest using selected air temperature and humidity combinations |
Bibliographic information |
Feb. 1987, Vol.58, No.2, p.119-124. Illus. 12 ref. |
Abstract |
Experimental evaluation of the effectiveness of an air-cooled vest in reducing thermal strain of subjects exercising in the heat (49°C dry bulb, 20°C dew point) in chemical protective clothing. At a metabolic rate of 175W, endurance times were 118min without the vest and 300min with the vest, with the subjects able to maintain a constant body temperature when wearing the vest. At a metabolic rate of 315W, endurance times were 73min without the vest, 242-300min with the vest, but constant body temperature could not be maintained even with the vest. |
Descriptors (primary) |
protective clothing; endurance limit; air-cooled suits; heat tolerance; heat load |
Descriptors (secondary) |
evaluation of equipment |