Abstract A rapid and specific method has been developed for the detection of trivalent arsenic (As). In sulphuric acid solution, As catalyses the reaction of osmium tetroxide with pyrocatechol to give a blue colour at room temperature. Many anions and cations do not interfere with the detection of As in water and gastric juice. The sensitivities were 0.25µg and 0.5µg/mL, respectively.
Descriptors (primary) arsenic and compounds; colorimetry; determination in biological matter
Descriptors (secondary) arsenic
Document type D - Periodical articles
Subject(s) Toxic and dangerous substances
Broad subject area(s)
Browse category(ies) Arsenic and compounds