Document ID (ISN) | 44138 |
CIS number |
85-986 |
ISSN - Serial title |
0005-3287 - Betriebssicherheit |
Year |
1985 |
Convention or series no. |
|
Author(s) |
Böhmüller H.P. |
Title |
You can eliminate fumes |
Original title |
Ohne Rauch geht's auch [in German] |
Bibliographic information |
1985, No.1, p.10. Illus. |
Abstract |
Description of a hand-held double-walled screen for welders (with filter glass). The wall facing the workpiece has exhaust slots connected to a ventilation system in the hollow handle. Because of direct fume elimination, there is relatively little air to evacuate. |
Descriptors (primary) |
local exhaust; welding and cutting; screens; welding fumes |
Descriptors (secondary) |
shielded-arc welding; face shields; electric welding |
Document type |
D - Periodical articles |
Subject(s) |
Heating, ventilation and climate
|
Broad subject area(s) |
|
Browse category(ies) |
Safety devices Ventilation Welding and cutting
|