Document ID (ISN)42681
CIS number 84-1629
ISSN - Serial title 0002-8894 - American Industrial Hygiene Association Journal
Year 1984
Convention or series no.
Author(s) Kring E.V., Damrell D.J., Henry T.J., DeMoor H.M., Basilio A.N., Simon C.E.
Title Laboratory validation and field verification of a new passive colorimetric air monitoring badge for sampling hydrogen sulfide in air
Bibliographic information Jan. 1984, Vol.45, No.1, p.1-9. Illus. 34 ref.
Abstract This dosimeter has been validated over the range of 1.8 to 164ppm-h (0.23-21 ppm H2S for 8h). Analysis is based on the Texas Air Control Board's molybdenum blue colorimetric method; colour-activated exposed badge solutions are read out on a spectrophotometer set at 580nm and using 10mm cells. The overall accuracy is ±16%; variations in temperature (10-40°C), relative humidity and face velocity (0.6-76m/s) do not affect badge performance. Unexposed badges are stable for 12 months refrigerated or 2 months at room temperature. Exposed badges can be stored for 1 week at room temperature or 1 month refrigerated. There are no significant interferences from other contaminants.
Descriptors (primary) hydrogen sulfide; sampling and analysis; passive dosimeters
Descriptors (secondary) spectrophotometric colorimetry; accuracy; evaluation of equipment
Document type D - Periodical articles
Subject(s) Toxic and dangerous substances
Broad subject area(s)
Browse category(ies) Inorganic sulfur compounds
Inorganic substances