Document ID (ISN) | 41812 |
CIS number |
84-805 |
ISSN - Serial title |
0025-7818 - Medicina del lavoro |
Year |
1983 |
Convention or series no. |
|
Author(s) |
Chiappino G., Miglior M., Terrana T. |
Title |
Contact lenses and work activity |
Original title |
Lenti a contatto e particolari attività lavorative [in Italian] |
Bibliographic information |
July-Aug. 1983, Vol.74, No.4, p.257-259. 7 ref. |
Abstract |
This review discusses: corneal lesions resulting from adhesion of airborne particles to the lens; absorption of irritating vapours by the lens material; local hypoaesthesia due to the lens itself; lesions due to hot, dry environments; formation of gas bubbles between the lens and cornea in sudden decompression; sudden detachment of the lens when forced ventilation helmets are worn; adhesion of the lens to the cornea as a result of exposure to infrared radiation and the electric arc. General prevention measures are proposed and suitable filter screens are recommended for workers exposed to infrared or electric arc radiation. English translation available from Canadian Centre for Occupational Health and Safety, 250 Main Street East, Hamilton, Ontario L8N 1H6, Canada. |
Descriptors (primary) |
corneal damage; eyes; contact lenses |
Descriptors (secondary) |
electric arc; translation; infrared radiation; round-up; welding and cutting |
Document type |
D - Periodical articles |
Subject(s) |
Occupational pathology
|
Broad subject area(s) |
|
Browse category(ies) |
Diseases of the eye and vision damage
|