CISDOC database
Document ID (ISN) | 41100 |
CIS number |
84-109 |
ISSN - Serial title |
0002-8894 - American Industrial Hygiene Association Journal |
Year |
1983 |
Convention or series no. |
|
Author(s) |
Meadows G.W., Rusch G.M. |
Title |
The measuring and monitoring of formaldehyde in inhalation test atmospheres |
Bibliographic information |
Feb. 1983, Vol.44, No.2, p.71-77. Illus. 12 ref. |
Abstract |
Two procedures for the determination of formaldehyde concentrations in animal testing inhalation chambers, using chromotropic acid, were evaluated. In the first, the chromogen was mixed with sulfuric acid prior to use, and in the second, the reagents were added sequentially. The 2nd procedure gave more reliable results. Collection of airborne samples of formaldehyde in impingers containing 1% aqueous sodium bisulfite provided more stable storage conditions than collection in water alone. When shipping samples, great care must be exercised to avoid contamination with materials commonly used for sample bottle caps and seals that can cause interferences. |
Descriptors (primary) |
formaldehyde; animal experiments; determination of concentration; sampling and analysis; inhalation chambers |
Descriptors (secondary) |
description of technique |
Document type |
D - Periodical articles |
Subject(s) |
Toxic and dangerous substances
|
Broad subject area(s) |
|
Browse category(ies) |
Aldehydes
|
|
|
|
|
|