Author(s) Adolfson J., Elnäs S., Sperling L.
Title Development of suitable diver's gloves
Original title Utveckling av funktionsdugliga dykarhandskar [in Swedish]
Bibliographic information Försvarets Forskningsanstalt, Huvudavdelning 5, 10254 Stockholm, Sweden, Nov. 1981. 34p. Illus. 20 ref.
Abstract Tests were carried out by 10 divers at depth of 5m in water at +0.1°C with a view to evaluating a 5-finger rubber glove worn over a synthetic-fibre inner glove. Sections cover: test environment (diving suit, glove system); test persons; test equipment and testing procedure (testing of hand motoricity, tactile discrimination, static grip strength and endurance; recording of temperatures and cardiac rhythm); presentation of results (hand, foot and body-core temperatures; thermal protection afforded by glove system; test results); discussion, conclusions and recommendation calling for tests at higher pressure (i.e. greater depths).
Descriptors (primary) protective gloves; protection against cold; ergonomics; diving
Descriptors (secondary) grip strength; Sweden; report; applied research; human experiments; body mechanics; design of equipment; hand
Document type E - Books, reports, proceedings
Subject(s) Personal protection
Broad subject area(s)
Browse category(ies) Ergonomics
Heat and cold
Hand and arm protection