Document ID (ISN) | 38693 |
CIS number |
82-1918 |
ISSN - Serial title |
0003-4878 - Annals of Occupational Hygiene |
Year |
1981 |
Convention or series no. |
|
Author(s) |
Benson G.B., Boyce G.E. |
Title |
A thermally-desorbable passive dosimeter for personal monitoring for acrylonitrile |
Bibliographic information |
1981, Vol.24, No.1, p.55-75. Illus. 6 ref. |
Abstract |
Description of the Monsanto passive dosimeter in which the collection medium is a porous polymer contained in a removable element that is analysed by thermal desorption/gas chromatography. Details are given of the laboratory evaluation of the dosimeter's performance in measuring atmospheric concentrations of acrylonitrile (effects of orientation, air velocity, concentration, sampling duration, high concentrations, short exposure times and profiled exposure). Results of field trials in a manufacturing chemical plant environment are also reported. Application of the dosimeter to the measurement of other organic pollutants is also considered. |
Descriptors (primary) |
personal sampling; passive dosimeters; acrylonitrile |
Descriptors (secondary) |
evaluation of equipment; description of equipment |
Document type |
D - Periodical articles |
Subject(s) |
Toxic and dangerous substances
|
Broad subject area(s) |
|
Browse category(ies) |
Cyano compounds
|