Convention or series no.
Author(s) Dinardi S.R., Sacco C.L., McLean-Shinaman C.
Title A gas handling system for ethylene oxide.
Bibliographic information Oct. 1980, Vol.41, No.10, p.766-769. 16 ref.
Abstract A safe and convenient apparatus for laboratory sampling and analysis using readily available stainless steel fittings is described. It provides for complete conversion of 100% ethylene oxide liquid to a vapour which is extractable from a sampling port for gas chromatographic analysis.
Descriptors (primary) ethylene oxide; sampling and analysis; laboratory equipment
Descriptors (secondary) description of equipment
Document type D - Periodical articles
Subject(s) Toxic and dangerous substances
Broad subject area(s)
Browse category(ies) Ethers
Ethylene oxide