Document ID (ISN) | 27342 |
CIS number |
77-1051 |
ISSN - Serial title |
0340-0131 - International Archives of Occupational and Environmental Health |
Year |
1976 |
Convention or series no. |
|
Author(s) |
Herber R.F.M. |
Title |
The application of a new carbon disulfide exposure test in occupational health. |
Bibliographic information |
15 Dec. 1976, Vol.38, No.2, p.115-120. 4 ref. |
Abstract |
The widely used iodo-azide test (IAT) for measuring exposure to carbon disulfide is compared with gas chromatographic determination (1) with electron capture detector (GC-ECD) and (2) with flame photometric detector (GC-FPD). The GC methods were consistent with each other but not with the IAT. The results obtained with these 3 methods in 23 exposed and 6 non-exposed workers are compared. The GC methods have both better sensitivity and specificity than IAT. For qualitative purposes the 2 GC methods are better suited than the IAT when exposure is below the TLV. The GC-FPD method especially gives a better relation with exposure and is more sensitive than the IAT. |
Descriptors (primary) |
carbon disulfide; urine monitoring; exposure tests |
Descriptors (secondary) |
viscose rayon industry; comparative study; gas chromatography; flame photometry |
Document type |
- |
Subject(s) |
Toxic and dangerous substances
|
Broad subject area(s) |
|
Browse category(ies) |
Inorganic substances Biological monitoring Inorganic sulfur compounds
|