Document ID (ISN) | 27228 |
CIS number |
77-969 |
ISSN - Serial title |
Gigiena truda i professional'nye zabolevanija |
Year |
1976 |
Convention or series no. |
|
Author(s) |
Il'ickaja A.V., Blohin V.S., Mel'nikov E.V. |
Title |
Noise produced by plasma spray coating, and hygiene measures to improve the technique |
Original title |
Šum pri plazmennom napylenii i gigieničeskoe obosnovanie optimal'nyh tehnologičeskih režimov [in Russian] |
Bibliographic information |
Apr. 1976, No.4, p.50-52. Illus. |
Abstract |
Results of these studies: gas flow rate and composition and the nozzle diameter of the torch have a determining influence on the noise level and spectrum. Reduction of the spraying rate, inversely proportional to the cross-sectional area of the nozzle, markedly reduces the noise level. Other noise control measures: use of plasma torches in which the powder to be sprayed is introduced before reaching the anode; increasing the proportion of argon in the gas mixture; acoustic enclosure of spray-coating booths. |
Descriptors (primary) |
noise; sound attenuation; plasma spray coating |
Descriptors (secondary) |
airflow noise; pressure-jet equipment; experimental determination; noise measurement; nozzles |
Document type |
- |
Subject(s) |
Noise, hearing and vibration
|
Broad subject area(s) |
|
Browse category(ies) |
Noise Surface treatment
|