Author(s) Strindberg L., Johansson L., Carlsson A., Ljungqvist E., Åstrand I.
Title Physiological load due to increased breathing resistance while wearing a filter respirator
Original title Fysiologisk belastning vid ökat andningsmotstand orsakat av andningsskydd [in Swedish]
Bibliographic information Arbete och hälsa - vetenskaplig skriftserie, 1974:5. Arbetarskyddsstyrelsen, Fack, 100 26 Stockholm 34, Sweden, 1974. 28p. Illus. 13 ref. Price: Swe-cr.8.00.
Abstract 12 young and 12 older healthy men performed exercise on a bicycle ergometer with and without a respirator. Work intensities were 50, 75, 100 and 125W and the exercise periods were 5min with a respirator, with an ordinary valve (for reference), and with free breathing. Older subjects had a higher mean value for pulmonary ventilation and a lower mean carbon dioxide level than the young subjects; they also had a significantly higher negative pressure in the mask at the 2 heaviest work loads. Young subjects experienced greater respiratory resistance in breathing through a respirator than in breathing through a valve at the 2 heaviest work loads. It is therefore recommended that respirators, such as MSA Comfo, should not be used in work calling for pulmonary ventilation rates higher than 40 l/min.
Descriptors (primary) air purifying respirators; breathing resistance; physical workload
Descriptors (secondary) pulmonary ventilation; comparative study; age-linked differences; ergometric tests
Document type E - Books, reports, proceedings
Subject(s) Personal protection
Broad subject area(s)