Title A simple method for controlling pollution due to beryllium
Original title Une méthode simple pour contrôler les contaminations dues au béryllium. [in French]
Bibliographic information Sep. 1973, No.9, p.418-424. Illus. 7 ref.
Abstract During the drawing from the kiln of beryllium oxide ceramics, local exhaust ventilation is provided by means of a vacuum pump coupled to a detachable filter by a flexible tube. The operator is thus protected from polluted air and the filter retains the substances which will serve to check the level of pollution. A simplified method is described for BeO dosage, based on the fluorescence of morin. An appendix gives a description of beryllium poisoning symptoms and means of medical prevention.
Descriptors (primary) local exhaust; beryllium; determination of concentration; dust; filtration sampling; beryllium oxide
Descriptors (secondary) detection by fluorescence; morin
Document type -
Subject(s) Dust, aerosols and related diseases
Broad subject area(s)
Browse category(ies) Ventilation