Document ID (ISN) | 19598 |
CIS number |
72-2754 |
ISSN - Serial title |
0722-6179 - Industrie-Elektrik und Elektronik |
Year |
1972 |
Convention or series no. |
|
Title |
Explosion protection in electrostatic coating |
Original title |
Explosionsschutz in der elektrostatischen Verfahrenstechnik [in German] |
Bibliographic information |
May 1972, Vol.17, No.10, p.240-241. |
Abstract |
Explosion prevention in electrostatic painting, spraying and powder coating is achieved by primary protection (adequate ventilation) backed up by secondary protection (usually intrinsic safety). Ignition at the spray nozzle is discussed, and safety measures related to current paths and workpieces are indicatd (earthing, selection of suitable current for spray unit to ensure intrinsic safety). |
Descriptors (primary) |
powder coating; electrostatic coating; explosion prevention |
Descriptors (secondary) |
intrinsic safety; earthing; ventilation; explosion hazards |
Document type |
D - Periodical articles |
Subject(s) |
Metal production and metalworking
|
Broad subject area(s) |
Fires, explosions and major hazards
|
Browse category(ies) |
Surface treatment Explosions
|