Document ID (ISN) | 111494 |
CIS number |
11-0222 |
ISSN - Serial title |
0007-9952 - Cahiers de notes documentaires - Hygiène et sécurité du travail |
Year |
2010 |
Convention or series no. |
ND 2337-221-10
|
Author(s) |
Galland B., Demey T., Henrard J., Martin P. |
Title |
Efficiency of saturation detectors for organic solvent mask purification cartridges |
Original title |
Efficacité des capteurs de saturation de cartouche de masques épurants pour les vapeurs de solvants organiques [in French] |
Bibliographic information |
Dec. 2010, No.221, p.17-24. Illus. 8 ref. |
Internet access |
ND 2337-221-10.pdf [in French]
|
Abstract |
The real-time measurement of compounds passing through purification cartridges is a way of assessing the efficiency of a respiratory protective device (RPD) for gases and vapours. Resistance-type semi-conductor gas saturation detectors were validated in the laboratory using test benches. Their properties allow highlighting the RPD cartridge saturation phenomenon. This article describes the means of testing developed for this application, provides a comparative survey of detector performance for various exposures to organic solvent vapours and discusses ways of adapting these detectors to RPD-based systems. |
Descriptors (primary) |
volatile substances; inorganic solvents; filtration efficiency; gas removing respirators; sorbent filters |
Descriptors (secondary) |
equipment testing; description of technique |
Document type |
D - Periodical articles |
Subject(s) |
Toxic and dangerous substances Personal protection
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection
|