Document ID (ISN) | 111486 |
CIS number |
11-0108 |
ISSN - Serial title |
0007-9952 - Cahiers de notes documentaires - Hygiène et sécurité du travail |
Year |
2010 |
Convention or series no. |
ND 2324-218-10
|
Author(s) |
Galland B., Henrard J., Martin P., Tran-Thi T., Crunaire S., Rivron C. |
Title |
A new approach to qualifying and quantifying monocyclic aromatic hydrocarbons (MAH ) in workplace atmospheres |
Original title |
Une nouvelle approche pour la qualification et la quantification des hydrocarbures aromatiques monocycliques (HAM) dans l'atmosphère des lieux de travail [in French] |
Bibliographic information |
Mar. 2010, No.218, p.45-50. Illus. 5 ref. |
Internet access |
ND 2324-218-10.pdf [in French]
|
Abstract |
Presently, monocyclic aromatic hydrocarbons are selectively detected in workplace atmospheres mostly by conventional methods, namely specifically, sampling on a medium and conducting a posteriori analysis in the laboratory. This article presents the concept of a new real-time analyzer, based on laboratory research and validated by INRS. Work is underway to design a prototype in the next few years. |
Descriptors (primary) |
aromatic hydrocarbons; workplaces; sampling and analysis; determination in air; description of technique |
Descriptors (secondary) |
France; reliability; public OSH institutions; research |
Document type |
D - Periodical articles |
Subject(s) |
Toxic and dangerous substances
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Aromatic hydrocarbons
|