Document ID (ISN) | 104003 |
CIS number |
05-377 |
ISSN - Serial title |
0007-9952 - Cahiers de notes documentaires - Hygiène et sécurité du travail |
Year |
2004 |
Convention or series no. |
INRS ND 2218-197-04
|
Author(s) |
Martin P., Rousseau R., Brand F. |
Title |
Performance determination of dust-removing respirators with standard filtration media |
Original title |
Détermination des performances des masques anti-poussières à média filtrant classique [in French] |
Bibliographic information |
4th Quarter 2004, No.197, p.21-29. Illus. 13 ref. |
Internet access |
http://www.hst.fr/inrs-pub/inrs01.nsf/IntranetObject-accesParReference/ND%202218/$File/ND2218.pdf [in French]
|
Abstract |
The objective of this study was to develop laboratory test methods for dust-removing respirators that best reproduce true conditions of use. Three series of tests were carried out: leakage and pressure tests for ventilated devices; pressure measurements at various flow rates for supplied-air masks; leakage and pressure tests for negative pressure masks. The findings will facilitate the further development of new methods for the laboratory validation of respirators that are more representative of true conditions of use, rendering it possible to carry out a critical analysis of test methods used for their certification. |
Descriptors (primary) |
France; equipment testing; respirators |
Descriptors (secondary) |
supplied air respirators; particulate removing respirators; description of technique; approval; positive supply filter respirators |
Document type |
D - Periodical articles |
Country / State or Province | France |
Subject(s) |
Personal protection
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection
|