ID (ISN) del documento | 60544 |
Número CIS |
93-1349 |
ISSN - Título de la serie |
Cahiers de notes documentaires - Sécurité et hygiène du travail |
Año |
1992 |
Número de serie |
|
Título |
Provisional guide for setting exposure limit values for electric and magnetic fields in the 50-60Hz frequency range |
Título original |
Guide provisoire pour l'établissement de limites d'exposition aux champs électriques et magnétiques aux fréquences de 50/60Hz [en francés] |
Información bibliográfica |
4th Quarter 1992, No.149, Note No.1897-149-92, p.487-495. 43 ref. |
Resumen |
This document, issued by the International Radiation Protection Association (IRPA), defines the quantities measured and units used, the limits for occupational and general public exposure (excluding the deliberate exposure of patients for diagnostic and therapeutic purposes), the methods for evaluating fields and the recommended protective measures. It also presents the arguments in favour of setting such exposure limits (based inter alia on studies already completed) and examines the particular case of the exposure of pacemaker users to "extremely low frequency" electric or magnetic fields. Originally published in the journal Health Physics (1990, Vol.58, No.1, p.113-122). |
Descriptores (primarios) |
valores umbrales; campos eléctricos; campos magnéticos; rayos de frecuencias radioeléctricas; limitación de la exposición; radiación no ionizante |
Descriptores (secundarios) |
traducción; medida de las magnitudes magnéticas |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Radiaciones
|
Broad subject area(s) |
Riesgos físicos
|
Navegación por categoria(s) |
Occupational exposure limits Electromagnetic fields Non-ionizing radiation Electricidad
|