Autor(es) Kihlberg S., Friberg M., Hagberg M., Hansson J.E., Jorulf L., Östergren C.E.
Título Vibration levels and health problems from work with nut runners
Título original Machines portatives d'assemblage - Intensité des vibrations induites - Problèmes de santé liés à leur utilisation [en francés]
Información bibliográfica 1st Quarter 1991, No.142, Note No.1818-142-91, p.87-92. Illus. 9 ref.
Resumen The most frequently used tools in a Swedish truck assembling factory are impact wrenches. In 1982, 23% of the workers were suffering from vibration-induced white finger (VWF) and 33% from numbness after 7-9yrs of exposure. New tools were introduced in the factory between 1984 and 1986. In 1987 almost all of the impact wrenches were changed to nut runners. Some screwdrivers, impulse wrenches and wrenches were also used. There was now no increase in the risk for VWF compared with the reference group, but a 16% prevalence of nocturnal tingling was still found, corresponding to a relative risk of 10 (Mantel-Haenszel odds ratio).
Descriptores (primarios) herramientas con motor portátiles; industria del automóvil; síndrome de Raynaud; vibración
Descriptores (secundarios) ingeniería de seguridad y salud; Suecia
Tipo de documento D - Artículos periódicos
País / Estado o ProvinciaSuecia
Tema(s) Ruido, audición, vibraciones
Broad subject area(s) Riesgos físicos
Navegación por categoria(s) Cardiovascular diseases
Motor vehicle manufacturing industry
Hand and portable tools
Vibration