ID (ISN) del documento54002
Número CIS 90-824
ISSN - Título de la serie 0301-0023 - Journal of the Society of Occupational Medicine
Año 1989
Número de serie
Autor(es) Stenton S.C., Kelly C.A., Walters E.H., Hendrick D.J.
Título Occupational asthma due to a repair process for polyethylene-coated electrical cables
Información bibliográfica Spring 1989, Vol.39, No.1, p.33-34. 7 ref.
Resumen The case of an electrical cable repairer is reported who presented with symptoms suggestive of occupational asthma. A supervised workplace challenge test confirmed this diagnosis and laboratory challenge studies implicated heated polyethylene repair tape containing the chemical cross-linking agent dicumyl peroxide as the cause. Similar cross-linking processes are widely used in the cable manufacturing industry and the possibility of occupational asthma occurring in other settings may need to be considered.
Descriptores (primarios) electricidad; fabricación de material eléctrico; asma alérgico; peróxido de cumeno
Descriptores (secundarios) substancias peligrosas; enfermedades respiratorias; estudio de caso
Tipo de documento D - Artículos periódicos
Tema(s) Electricidad
Broad subject area(s) Medicina del trabajo, epidemiología
Navegación por categoria(s) Manufacturing of electrical appliances and equipment
Electricidad
Alergias
Diseases of the respiratory system (except for pneumoconiosis & similar)