Autor(es) |
Stenton S.C., Kelly C.A., Walters E.H., Hendrick D.J. |
Título |
Occupational asthma due to a repair process for polyethylene-coated electrical cables |
Información bibliográfica |
Spring 1989, Vol.39, No.1, p.33-34. 7 ref. |
Resumen |
The case of an electrical cable repairer is reported who presented with symptoms suggestive of occupational asthma. A supervised workplace challenge test confirmed this diagnosis and laboratory challenge studies implicated heated polyethylene repair tape containing the chemical cross-linking agent dicumyl peroxide as the cause. Similar cross-linking processes are widely used in the cable manufacturing industry and the possibility of occupational asthma occurring in other settings may need to be considered. |
Descriptores (primarios) |
electricidad; fabricación de material eléctrico; asma alérgico; peróxido de cumeno |
Descriptores (secundarios) |
substancias peligrosas; enfermedades respiratorias; estudio de caso |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Electricidad
|
Broad subject area(s) |
Medicina del trabajo, epidemiología
|
Navegación por categoria(s) |
Manufacturing of electrical appliances and equipment Electricidad Alergias Diseases of the respiratory system (except for pneumoconiosis & similar)
|