ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento52698
Número CIS 89-1967
Año 1988
Número de serie Undersökningsrapport 1988:7
Autor(es) Waernbaum G., Vahemann R.
Arbetsmiljöinstitutet
Título Sampling and analysis of hexamethylenetetramine in air
Título original Provtagning och analys av hexametylentetramin i luft [en sueco]
Información bibliográfica Arbetarskyddsstyrelsen, Publikationsservice, 171 84 Solna, Sweden, 1988. 12p. 3 ref.
Resumen Report on a new method for the determination of the concentration of hexamethylenetetramine (HMTA) in air. The detection limit was 0.1µg per sample. Air was sampled by passage through distilled water, and free formaldehyde was removed by thin layer chromatography. Samples were scraped from the thin-layer plates, extracted with water and treated with chromotropic acid. HMTA was finally determined by UV spectrophotometry. The stability of HMTA in water was found to be acceptable with a storage period of one week.
Descriptores (primarios) dosificación en el aire; hexametilenotetramina
Descriptores (secundarios) espectrofotometría en el ultravioleta; informe; cromatografía en capa delgada; descripción del procedimiento; toma de muestras y análisis
Tipo de documento E - Libros, informes, actas
Tema(s) Sustancias tóxicas y peligrosas
Broad subject area(s) Riesgos químicos
Navegación por categoria(s) Heterocyclic compounds