ID (ISN) del documento | 51743 |
Número CIS |
89-1018 |
ISSN - Título de la serie |
0098-7484 - Journal of the American Medical Association |
Año |
1988 |
Número de serie |
|
Autor(es) |
Brundage J.F., Scott R.M., Lednar W.M., Smith D.W., Miller R.N. |
Título |
Building-associated risk of febrile acute respiratory diseases in army trainees |
Información bibliográfica |
8 Apr. 1988, Vol.259, No.14, p.2108-2112. Illus. 51 ref. |
Resumen |
Airborne transmission of infectious agents and associations of indoor air pollutants with respiratory illnesses are well documented. At four Army training centres during a 47-month period, incidence rates of febrile acute respiratory disease were compred between basic trainees in modern (energy-efficient design and construction) and old barracks. Rates of febrile acute respiratory disease were significantly higher among trainees in modern barracks (adjusted relative risk estimate, 1.51; 95% confidence interval, 1.46 to 1.56), and relative risks were about the same at the 4 centers. These results support the hypothesis that tight buildings with closed ventilation systems, designed to conserve energy, significantly increase risks of respiratory-transmitted infection among congregated, immunologically susceptible occupants. |
Descriptores (primarios) |
enfermedades infecciosas; edificios; enfermedades respiratorias |
Descriptores (secundarios) |
gripe; Estados Unidos; vacunación; sistemas de ventilación; valoración de los resultados; morbilidad |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Patología profesional
|
Broad subject area(s) |
Riesgos biológicos
|
Navegación por categoria(s) |
Diseases of the respiratory system (except for pneumoconiosis & similar) Bacterial and parasitic diseases Viral diseases (other than aids) Gripe
|