ID (ISN) del documento | 51376 |
Número CIS |
89-612 |
Año |
1987 |
Número de serie |
|
Autor(es) |
Howie R.M., Coleman G.C., Graveling R.A., Graves R.G., Nicholl A.G.M., Groat S., Wildblood R., Crawford N.P., Dodgson J. |
Título |
Development of a powered helmet respirator suitable for use in coalmines |
Información bibliográfica |
Institute of Occupational Medicine, Roxburgh Place, Edinburgh EH8 9SU, United Kingdom, 1987. 104p. Illus. 19 ref. Appendices. Price: GBP 10.00. |
Resumen |
Contents of this report: work programme; ergonomic assessment of the AHG powered helmet respirator (PHR); development of a prototype PHR; development of fan/filter systems, headshells, visor assemblies; specification of the Institute of Occupational Medicine (IOM) prototype PHR; ergonomic assessment of the final IOM prototype PHR; mobility, communication, physiological and wearer acceptance trials. |
Descriptores (primarios) |
aparatos filtrantes por acción mecánica; mineria del carbón; mascaras aireadoras |
Descriptores (secundarios) |
cascos antipolvos; valoración del material; valoración ergonómica; informe; Reino Unido |
Tipo de documento |
E - Libros, informes, actas |
Tema(s) |
Protección individual
|
Broad subject area(s) |
Riesgos químicos
|
Navegación por categoria(s) |
Mining and quarrying Respiratory protection
|