ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento40374
Número CIS 83-1220
Año 1983
Número de serie FP 8305
Título Higher risk? Lower voltage
Título original Meer risico's? Minder spanning [en holandés]
Información bibliográfica Veiligheidsinstituut, Postbus 5665, 1007 AR Amsterdam, Netherlands, 1983. 4p. Illus.
Resumen Data sheet for the information of all workers who may be called upon to use electric tools, hand lamps, etc., in highly conductive environments (damp locations, metal enclosures). Contents: elevated risks due to electrical faults in the equipment and/or contact with conducting surfaces (including damp clothing or skin); necessity of low voltage; protective value of an isolating transformer; possibility of welding with an isolating transformer having a relay which limits the voltage between the welding electrode and the grounded environment to 42V as soon as the arc is broken; suggestions for even lower voltages under dangerous conditions.
Descriptores (primarios) Países Bajos; seguridad eléctrica; tensión muy baja
Descriptores (secundarios) humedad; soldadura eléctrica; nota informativa; lámparas de linternas; herramientas eléctricas; transformadores de aislamiento
Tipo de documento F - Notas informativas, directrices prácticas, normas
Tema(s) Electricidad
Broad subject area(s)
Navegación por categoria(s) Electricidad