ID (ISN) del documento | 39441 |
Número CIS |
83-405 |
ISBN(s) |
0-905927-90-7 |
Año |
1982 |
Número de serie |
|
Autor(es) |
Martin E.B.M. |
Título |
Adventitious x radiation from high-voltage equipment: Hazards and precautions |
Información bibliográfica |
Science Reviews Ltd., 28 High Ash Drive, Leeds LS17 8RA, United Kingdom, 1982. 43p. 99 ref. Price: £5.00. |
Resumen |
Contents: introduction; definition of units; production of x-radiation; biological effects; protection standards; radiation monitoring; shielding and control of access; medical and dosimetric supervision; types of high-voltage equipment liable to give rise to adventitious x-radiation (television receivers and cathode ray tubes; thermionic rectifiers, regulators and transmitting tubes; thyratrons and high-voltage mercury arc switches; magnetrons and klystrons; cold cathode discharge tubes and high-voltage vacuum switches and capacitors; electron-beam welders, evaporators and zone melting ovens; electron microscopes and microprobe analysers; positive ion accelerators); discussion and bibliography. |
Descriptores (primarios) |
alta tensión; rayos X; material eléctrico; material electrónico |
Descriptores (secundarios) |
radioprotección; informe; rectificadores; tubos electrónicos; vigilancia médica; pantallas de radioprotección; control de la irradiación; dosimetría; efectos biológicos; aceleradores de partículas |
Tipo de documento |
E - Libros, informes, actas |
Tema(s) |
Radiaciones
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Ionizing radiation Electricidad
|