ID (ISN) del documento | 33308 |
Número CIS |
80-670 |
ISSN - Título de la serie |
0355-3140 - Scandinavian Journal of Work, Environment and Health |
Año |
1979 |
Número de serie |
|
Autor(es) |
Tossavainen A. |
Título |
Determination of quartz on membrane filters by X-ray diffraction. |
Información bibliográfica |
Dec. 1979, Vol.5, No.4, p.379-385. 21 ref. |
Resumen |
The method was developed with particular reference to the foundry industry, where determination of quartz in small dust samples is often required. Analysis is done directly on a collecting cellulose ester membrane filter. Quantitation is achieved by measurement of the quartz line intensities with a digital integrator and comparison of these values with calibration standards. Overall precision is 8%. Accuracy of quartz analysis of foundry dusts was within 10% at the 1-10mg level of total loading. Detection limit for quartz was <0.1mg. |
Descriptores (primarios) |
sílice; fundiciones; análisis de los polvos; difractometría por rayos x |
Descriptores (secundarios) |
reparto granulométrico; descripción del procedimiento; muestreo por filtración; tamano de las particulas |
Tipo de documento |
- |
Tema(s) |
Polvos, aerosoles
|
Broad subject area(s) |
|
Navegación por categoria(s) |
Foundries, metalcasting and forging operations
|