ID (ISN) del documento | 111325 |
Número CIS |
10-0852 |
ISSN - Título de la serie |
1545-9624 - Journal of Occupational and Environmental Hygiene |
Año |
2011 |
Número de serie |
|
Autor(es) |
Rengasamy S., Miller A., Eimer B.C. |
Título |
Evaluation of the filtration performance of NIOSH-approved N95 filtering facepiece respirators by photometric and number-based test methods |
Información bibliográfica |
Jan. 2011, Vol.8, p.23-30. Illus. 36 ref. |
Resumen |
N95 particulate filtering facepiece respirators are certified by measuring penetration levels photometrically with a presumed severe case test method using charge neutralized NaCl aerosols at 85L/min. However, penetration values obtained by photometric methods have not been compared with count-based methods using contemporary respirators composed of electrostatic filter media and challenged with both generated and ambient aerosols. To understand the effects of particle charge and detection methods, penetration levels for five filtering facepiece respirators were measured using NaCl aerosols with the aerosol challenge and test equipment employed in the NIOSH respirator certification method, and compared with an ultrafine condensation particle counter method. Findings are discussed. |
Descriptores (primarios) |
aerosoles; eficacia de la filtración; pruebas del material; aparatos filtrantes por acción mecánica |
Descriptores (secundarios) |
estudio comparado; fiabilidad; descripción del procedimiento |
Tipo de documento |
D - Artículos periódicos |
Tema(s) |
Protección individual
|
Broad subject area(s) |
Riesgos químicos
|
Navegación por categoria(s) |
Personal protection Respiratory protection
|