ILO Home
Volver a la página de entrada
Site map | Contact us English | Français

Base de datos CISDOC

ID (ISN) del documento111325
Número CIS 10-0852
ISSN - Título de la serie 1545-9624 - Journal of Occupational and Environmental Hygiene
Año 2011
Número de serie
Autor(es) Rengasamy S., Miller A., Eimer B.C.
Título Evaluation of the filtration performance of NIOSH-approved N95 filtering facepiece respirators by photometric and number-based test methods
Información bibliográfica Jan. 2011, Vol.8, p.23-30. Illus. 36 ref.
Resumen N95 particulate filtering facepiece respirators are certified by measuring penetration levels photometrically with a presumed severe case test method using charge neutralized NaCl aerosols at 85L/min. However, penetration values obtained by photometric methods have not been compared with count-based methods using contemporary respirators composed of electrostatic filter media and challenged with both generated and ambient aerosols. To understand the effects of particle charge and detection methods, penetration levels for five filtering facepiece respirators were measured using NaCl aerosols with the aerosol challenge and test equipment employed in the NIOSH respirator certification method, and compared with an ultrafine condensation particle counter method. Findings are discussed.
Descriptores (primarios) aerosoles; eficacia de la filtración; pruebas del material; aparatos filtrantes por acción mecánica
Descriptores (secundarios) estudio comparado; fiabilidad; descripción del procedimiento
Tipo de documento D - Artículos periódicos
Tema(s) Protección individual
Broad subject area(s) Riesgos químicos
Navegación por categoria(s) Personal protection
Respiratory protection