Abstract Thirty volunteers in six companies took part in a survey to measure the performance of negative-pressure gas respirators with no powered ventilation. Two full-face masks and five half-masks were tested. Each mask was fitted with a filter adapted to the solvent to which operatives were exposed. A new filter was used for each test. The efficiency of the masks was gauged by taking simultaneous readings of pollutant gas levels inside the masks (actual exposure) and outside the masks (potential exposure). The pollutant gases were generated by solvent mixtures. The study produced the following findings: only one mask was shown to be inefficient; there was little or no difference in the performances of the other six; mask leakage in actual working conditions is about 10%; leakage is higher than levels usually found in the literature (between 2% and 4%). The variability of results excludes prediction of the effectiveness of negative-pressure gas respirators in industrial settings.
Descriptors (primary) gas removing respirators; equipment testing; reliability
Descriptors (secondary) filtration efficiency; evaluation of equipment; respirators; solvents; exposure evaluation; negative pressure
Document type D - Periodical articles
Country / State or ProvinceFrance
Subject(s) Personal protection
Broad subject area(s) Chemical safety
Browse category(ies) Respiratory protection