Author(s) |
Crutchfield C.D., Park D.L. |
Title |
Effect of leak location on measured respirator fit |
Bibliographic information |
June 1997, Vol.58, No.6, p.413-417. 15 ref. |
Abstract |
In a study to assess how well current respirator fit-test systems detect leakage, known sources of leakage were introduced at three fixed locations on half-mask and full-face respirators mounted on a headform-breathing machine system. Fit-tests were performed with an ambient aerosol system and a controlled negative pressure (CNP) system. The ambient aerosol system detected an average of 37.2% of the known leakage; there were significant differences in leakage measurements as a function of leak location and mask type. The CNP system detected an overall average of 97.9% of the known leakage; results were not affected by leak location or mask type. |
Descriptors (primary) |
leakage testing; respirators |
Descriptors (secondary) |
evaluation of technique |
Document type |
D - Periodical articles |
Country / State or Province | USA |
Subject(s) |
Personal protection
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection
|