ILO Home
Go to the home page
Site map | Contact us Français | Español

CISDOC database

Document ID (ISN)64036
CIS number 95-707
ISSN - Serial title 0009-286X - Chemie-Ingenieur-Technik
Year 1994
Convention or series no.
Author(s) Hafkesbrink S., Schecker H.G., Hermann K.
Title Application of jet condensers in a blow-down system
Original title Einsatz von Strahlkondensatoren in einem Blow-down System [in German]
Bibliographic information June 1994, Vol.66, No.6, p.871-873. Illus. 3 ref.
Abstract A blow-down system for the prevention of explosion propagation in chemical reactors comprises separate cooling systems for the liquid and vapour phases. A cooling system for the vapour phase was tested in model experiments with 2 mixtures of methanol, nitrogen, and water or refrigerant R113, nitrogen and water at different conditions. The vapour phase carried the cooling agent on its way to a mixing nozzle where intense heat exchange caused the gas to condense. Installation of the condensation vessel inside the blow-down system renders the method suitable for a wide variety of conditions.
Descriptors (primary) heat exchange; prevention of explosion propagation; explosion suppression; chemical industry; pressure limiting devices; exothermic reactions
Descriptors (secondary) pressure vessels and systems; safety by design; tests on models
Document type D - Periodical articles
Country / State or ProvinceGermany
Subject(s) Chemicals, plastics and rubber
Broad subject area(s) Fires, explosions and major hazards
Browse category(ies) Chemical industry
Heat and cold
Explosions