Document ID (ISN) | 58188 |
CIS number |
92-901 |
ISSN - Serial title |
0022-443X - Journal of Science of Labour - Rōdō Kagaku |
Year |
1991 |
Convention or series no. |
|
Author(s) |
Kimura K. |
Title |
A study on facepiece-to-face fitting of dust respirators (Report 3) - On the mask fitting tester |
Original title |
Bōjin masuku no ganmen e no mitchakusei ni kansuru kenkyū - dai-3-hō - mask fitting tester ni tsuite [in Japanese] |
Bibliographic information |
10 Nov. 1991, Vol.67, No.11, p.517-524. 7 ref. |
Abstract |
There are on the market in Japan 2 types of dust respirators complying with Ministry of Labour standards: replaceable-cartridge dust respirators and disposable dust respirators. According to the provisions of the standards, a replaceable-cartridge dust respirator is required to provide a device which enables the wearer to check the facepiece-to-face fitting easily at any time, but a disposable dust respirator is not required to have such a check system. A Mask Fitting Tester was developed and the results of tests using it are reported. The Tester includes a particle counter that can count the number of particles with a diameter greater than 0.7µm. The Tester quantitatively and easily tests mask fit. The measurement can be done without modifying the dust respirator and takes about 1 minute. Tests conducted with the newly developed Tester gave penetration rates of more than 10 percent for several disposable dust respirators even when the subjects had fitted them carefully. |
Descriptors (primary) |
leakage testing; particulate removing respirators |
Descriptors (secondary) |
description of technique; description of equipment |
Document type |
D - Periodical articles |
Country / State or Province | Japan |
Subject(s) |
Dust, aerosols and related diseases
|
Broad subject area(s) |
Chemical safety
|
Browse category(ies) |
Respiratory protection
|